Live Engineering Dashboard

Well Testing Toolbox

Interactive Tools

Engineering calculators and conversion utilities for field work.

Gas Rate Inputs

Choke Calibration (Erosion Check)

Input your Actual Separator Rate to find the true effective choke size.

Effective Diameter Calculation:

$$D_{eff} = 128 \times \sqrt{\frac{Q_{mscf/d} \times \sqrt{T_R \times \gamma_g \times Z}}{\pi \times C \times P_{psia} \times C_d}}$$
Erosion & Washout Guide
Variance Status Action Required
< 1.5/64"IntactNormal operations.
1.5 - 3.0WornMonitor closely for sand production.
> 3.0/64"Washed OutSwitch to standby choke and inspect bean.